Where Do I Get a Grundfos Pump Seal?
Short answer: from us. We select and supply equivalent mechanical seals to suit Grundfos pumps across the range - multistage, end-suction, in-line and circulator. Send us the pump plate details and a photo of the old seal, and we identify the right seal and quote for it.
Start with the pump plate
Every Grundfos pump carries a model code, and on many ranges the last letters of that code are the seal code. A CR 20-17 A-F-A-E-HQQE, for example, ends in HQQE - a balanced cartridge seal with silicon carbide faces and EPDM elastomers. Send us the full model code and serial number and we know exactly which seal the pump takes.
Two posts go deeper. what the seal code letters mean and the difference between CR, CRI and CRN.
The main Grundfos ranges and their seals
CR and CRN vertical multistage pumps use a cartridge seal that comes out as one unit, identified by the seal code on the plate.
NB, NK and TP end-suction and in-line pumps use standard-dimension (EN 12756) mechanical seals, single or double, matched to the liquid.
UP and UPS circulators are different again: they are glandless canned-rotor pumps with no shaft seal at all. If one of those is leaking, it is not a seal job - tell us and we will tell you straight.
Equivalent seals, checked per enquiry
We supply equivalent seals, not genuine Grundfos parts, and we say so plainly. Every enquiry is checked against the pump model, the seal code and the liquid before we quote, so listing Grundfos here does not mean every model is covered. Older and obsolete models are worth asking about - identifying unmarked seals is a large part of what we do.
Common questions
Where can I get a Grundfos seal in the UK?
From us. Email the full model code and serial number from the pump plate, plus a photo of the old seal if you have one, and we will identify the equivalent seal and quote for it.
What do the letters at the end of my Grundfos model code mean?
On many ranges they are the seal code. HQQE, for example, means a balanced cartridge seal with silicon carbide faces and EPDM elastomers. Our post on the HQQE code explains each letter.
My UPS circulator is leaking - can you replace the seal?
There is no seal to replace - UP and UPS circulators are glandless, with the rotor sealed inside a can. A leak there points to the pump body or gaskets. Send us a photo and we will tell you what you are looking at.
Solutions related to this article
If this failure mode sounds familiar, these are the products and services that usually fix it.
- Cartridge SealsPre assembled seal units that remove setting errors on pumps, mixers and agitators.View details
- Component SealsSeal faces, springs, bellows and secondary seals in carbon, silicon carbide and tungsten carbide.View details
- FFKM O-RingsPerfluoroelastomer O-rings for aggressive chemistry and temperatures to 325C.View details
Director, Acumen Seals & Pumps Limited
Published on 2026-11-19
45 years in engineering and 36 years in sealing. Andrew specifies, supplies and troubleshoots mechanical seals, FFKM elastomers and pump sealing systems for UK industry.
More about Andrew